Compaq 1850R Server User Manual


 
3-35
Compaq ProLiant 1850R Servers Maintenance and Service Guide
Fixed Disk Drive Test Error Codes
The 1700 series of Diagnostic error codes identifies failures with fixed disk drives, fixed disk
drive controller boards, fixed disk drive cabling, and system board functions. Corrective action
may require replacement of fixed disk drive cables, fixed disk drive controller boards, fixed
disks, or the system board assembly. If your system uses a drive array controller, see the
section for Drive Array Advanced Diagnostics (DAAD).
Table 3-11
Fixed Disk Drive Test Error Codes
Error Code Description Recommended Action
1700-xx
1701-xx
1702-xx
1703-xx
1704-xx
1705-xx
1708-xx
1709-xx
1710-xx
1715-xx
1716-xx
1717-xx
1719-xx
1736-xx
1799-xx
Fixed disk ID drive types test failed.
Fixed disk format test failed.
Fixed disk read test failed.
Fixed disk write/read/compare test failed.
Fixed disk random seek test failed.
Fixed disk controller test failed.
Fixed disk format bad track test failed.
Fixed disk reset controller test failed.
Fixed disk park head test failed.
Fixed disk head select test failed.
Fixed disk conditional format test failed.
Fixed disk ECC* test failed.
Fixed disk drive power mode test failed.
Drive Monitoring failed.
Invalid fixed disk drive type failed.
The following steps apply to error codes
1700-xx
through 1799-xx:
1. Run the System Configuration Utility and
verify the drive type.
2. Replace the fixed disk drive signal and
power cables and retest.
3. Replace the fixed disk drive controller
and retest.
4. Replace the fixed disk drive and retest.
5. Replace the system board and retest.
* Error Checking and Correcting