Compaq 1850R Server User Manual


 
3-18 Diagnostic Tools
POST Error Messages
continued
Error Code
Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
1769-Slot x Drive
Array - Drive(s)
disabled due to
failure during
expand. Select
F1
to continue
with logical
drives disabled.
Select
F2
to
accept data loss
and to re-enable
logical drives.
None SMART-2 Controller
error.
Data has been lost while
expanding the array, therefore
the drives have been temporarily
disabled. Press
F2
to accept the
data loss and re-enable the
logical drives. Restore data from
backup.
1771-Primary
Disk Port
Address
Assignment
Conflict
None Internal and external
hard drive controllers are
both assigned to the
primary address.
Run the System Configuration
Utility
and correct.
1772-Secondary
Disk Port
Address
Assignment
Conflict
None Address Assignment
Conflict. Internal and
external hard drive
controllers are both
assigned to the
secondary address.
Run the System Configuration
Utility
and correct.
1773-Primary
Fixed Disk Port
Assignment
Conflict
None Fixed disk drive error. Run the System Configuration
Utility
and correct.
1774-Slot x Drive
Array - Obsolete
data found in
Array
Accelerator.
Select
F1
to
discard contents
of Array
Accelerator.
Select
F2
to
write contents of
Array
Accelerator to
drives.
None SMART-2 Controller
error.
Data found in Array Accelerator is
older than data found on drives.
Press
F1
to discard the older data
in the Array Accelerator and
retain the newer data on the
drives.