3-29
Compaq ProLiant 1850R Servers Maintenance and Service Guide
Primary Processor Test Error Codes
The 100 series of Diagnostic error codes identifies failures with processor and system board
functions. Corrective action may require replacement of system boards or processor assemblies
(either processor boards or system boards that include the processor).
Table 3-2
Primary Processor Test Error Codes
Error Code Description Recommended Action
101-xx CPU test failed Replace the processor board and retest.
103-xx
104-xx
105-xx
106-xx
DMA page registers test failed.
Interrupt controller master test failed.
Port 61 error.
Keyboard controller self-test failed.
For error codes 103-xx through 106-xx,
replace the processor board and retest.
107-xx
108-xx
109-xx
CMOS RAM test failed.
CMOS interrupt test failed.
CMOS clock load data test failed.
The following steps apply to error codes
107-xx through 109-xx:
1. Replace the battery/clock module and
retest.
2. Replace the system board and retest.
110-xx
111-xx
112-xx
113-xx
Programmable timer load data test failed.
Refresh detect test failed.
Speed test slow mode out of range.
Protected mode test failed.
For error codes 110-xx through 113-xx,
replace the system board and retest.
114-xx Speaker test failed. 1. Verify the speaker connection and
retest.
2. Replace the speaker and retest.
3. Replace the system board and retest.
116-xx Cache test failed. Replace the system board and retest.
122-xx
123-xx
Multiprocessor Dispatch test failed.
Interprocessor Communication test failed.
The following steps apply to error codes
122-xx
through 123-xx:
1. Check the system configuration and
retest.
2. Replace the processor board and retest.
3. Replace the system board and retest.
199-xx Installed devices test failed. 1. Check the system configuration and
retest.
2. Verify cable connections and retest.
3. Check switch and/or jumper settings
and retest.
4. Run the Configuration utility and retest.
5. Replace the processor board and retest.
6. Replace the system board and retest.