Compaq Interconnect Switch Switch User Manual


 
Configuring the GbE Interconnect Switch Using the Web-Based Management Interface
4-46 Compaq ProLiant BL p-Class GbE Interconnect Switch User Guide
COMPAQ CONFIDENTIAL Codename: Vanilla Part Number: 263680-001 Last Saved On: 4/23/02 10:02 AM
Record Number—Displays the number of times the GbE Interconnect Switch will be
polled. This setting can be between 20 and 200. The default value is 20.
ExDefer—Counts the number of frames for which the first transmission attempt on a
particular interface was delayed because the medium was busy.
LateColl—Counts the number of times that a collision is detected later than 512 bit-
times into the transmission of a packet.
ExColl—Counts the number of frames that experienced 16 collisions during transmission
and were aborted.
SingColl—Counts the number frames that experienced exactly one collision during
transmission.
Coll—Counts the number of collisions that occurred during the transmission of a frame.
Show/Hide—Displays or hides ExDefer, LateColl, CRCError, SingColl, and Coll errors.
Click Clear to reset the counters.
Monitoring Packet Size
The Web Manager allows packets received by the GbE Interconnect Switch, arranged in
six groups, to be viewed as either a line graph or a table.