Dell 2.3 Switch User Manual


 
3. Select the bundle for your host and click Next.
4. Select the desired firmware updates and click Next. Components that are either a downgrade, already up-to-date,
or currently scheduled for update are not selectable. If you select the Allow Components to be Downgraded check
box, select the options that are listed as Downgrade. Selecting this option is only recommended to advanced users
who understand the implications of downgrading firmware.
5. Select the desired restart option.
Enter maintenance mode, apply updates, and restart.
Host goes into maintenance mode. If the host cannot enter maintenance mode, then the host is not restarted
and the update is applied during the next reboot. Select the Exit maintenance mode after firmware update
completes check box, to exit maintenance mode after the update.
Apply updates on next reboot.
To avoid a service interruption, it is recommended that the host enters maintenance mode before the reboot.
Apply updates and force reboot without entering maintenance mode.
The update is applied, and a reboot occurs even if the host is not in maintenance mode. This method is not
recommended.
6. Click Finish.
7. To verify that the update was successful, in Dell Management Center, select Job QueueInventory History
Run Now, and to see the new versions, go to vSphere Client OpenManage Integration tab and click Firmware.
Updating Older Firmware Versions
Firmware must be at a minimum level for the Firmware Update Wizard to run. When it is not, you are offered options to
help update your firmware, prior to running the Firmware Update Wizard. Typically, firmware installed earlier than July
29, 2009 requires you to download and run an ISO file, see Firmware Updates. For firmware installed between July 29,
2009 and prior to Oct. 14, 2010, you are offered an ISO bundle to automatically install from the OpenManage Integration
for VMware vCenter. Firmware updated after October 14th, 2010 runs the Firmware Update Wizard. Firmware updates
are run from vSphere Client on the host OpenManage Integration tab. To set up the repository, see Setting Up The
Firmware Repository .
To update older firmware versions:
1. In vSphere Client, on the OpenManage Integration tab, under Host Actions, click Run Firmware Update Wizard.
The Update Required dialog displays when your host is at a lower level of firmware than the wizard supports. You
will either be asked to download and run an ISO file or be given a bundle of updates to run.
2. In the Update Required dialog box, do one of the following:
To automatically exit maintenance mode after the firmware update, select the Exit maintenance mode after
firmware update completes check box.
To enter maintenance mode to examine and/or test the machine before adding it back to the cluster, do not
check the check box.
3. Click Update.
4. The Success dialog box tells you that an update is now in progress.
If you chose to Exit maintenance mode after firmware update completes, the firmware update puts the host into
maintenance mode and then reboots automatically. Otherwise, it stays in maintenance mode.
5. Refer to the Recent Tasks area of the vSphere Client to watch the update progress.
After this procedure, run the Firmware Update Wizard again to make sure your firmware is completely updated.
Running the Update Firmware Wizard for Clusters and Datacenters
This functionality is only available for 11th and later generations of Dell servers that have either an iDRAC Express or
iDRAC Enterprise. If your firmware was installed on or after October 14th, 2010, you can automatically update your
49