Dell 2.3 Switch User Manual


 
Version Affected: All
Why is the DNS configuration settings restored to original settings after appliance reboot
if using DHCP for appliance IP and DNS settings overwritten
There is a known defect where statically assigned DNS settings are replaced by values from DHCP. This can happen
when DHCP is used to obtain IP settings, and DNS values are assigned statically. When the DHCP lease is renewed or
the appliance is restarted the statically assigned DNS settings are removed. Resolution: Statically assign IP settings
when the DNS server settings will be different from DHCP.
Version Affected: All
Why did my system not enter maintenance mode when I performed a one-to-many
firmware update?
Some firmware updates do not require rebooting the host. In that case, the firmware update is performed without
putting the host into maintenance mode.
Even if my repository has bundles for selected 11G system, why is firmware update
showing that I have no bundles for Firmware Update?
When I added a host to the connection profile in lockdown mode, the inventory kicked off but failed stating that “No
Remote Access Controller was found or Inventory is not supported on this host.” Inventory is supposed to work for a
host in lockdown mode, right?
If you put the host in lockdown mode or remove a host from lockdown mode, you must wait 30–minutes before
performing the next operation on the If I pick a 11G host for firmware update, the firmware update wizard will not show
any bundles even if the repository provided has bundles for that system. This will happen because the 11G host might
not configured for OMSA to send traps to OpenManage Integration.
Resolution: Ensure that the host is compliant using the host Compliance screen of OpenManage Integration desktop
client. If it is not compliant, use the fix Host Compliance to get it compliant.
Version Affected: 2.2 and 2.3
Why Does My ESX / ESXi Deployment Fail on Servers Having a PERC S300 Boot Controller?
Deployments of OpenManage Integration for VMware vCenter using different ESX/ESXi versions on Dell PowerEdge
servers with the PERC S300 boot controller failed. The Dell customized ESX/ESXi operating systems do not carry the
driver for the PERC S300 boot controller, which causes the boot controller/HDD not to be recognized during operating
system installation. Servers with PERC S300 boot controllers are not supported for OpenManage Integration for VMware
vCenter deployments.
How Come I See An Error Message Displayed After Clicking The Firmware Link?
If you have a slow network speed (9600BPS), you may get a Communication Error Message. This error message may
display when you click the Firmware link in the vSphere Client for the OpenManage Integration for VMware vCenter. It
happens when the connection times out while trying to obtain the Software Inventory list. Microsoft Internet Explorer
initiates this timeout. For Microsoft Internet Explorer versions 9/10, the default “Receive Time out” value is set to 10
seconds. Fix this issue by using the following steps.
83