Emerson PME1 Network Router User Manual


 
Monitor: Errors and Screen Messages
PmT1 and PmE1 User’s Manual 10002367-02
8-28
mul
multiplies two integers in decimal (the default), binary, octal, or hexadecimal from the
monitor.
The default numeric base is decimal. Specify hex by typing “:16” at the end of the value,
octal by typing “:8” or binary by typing “:2.” The result of the operation is displayed in hex,
decimal, octal, and binary.
Definition:
mul number1 number2
rand
is a linear congruent random number generator that uses a function Seed and a variable
Value. The random number returned is an unsigned long.
Definition:
rand
sub
subtracts two integers in decimal (the default), binary, octal, or hexadecimal. number2 is
subtracted from number1.
The default numeric base is decimal. Specify hexadecimal by typing “:16” at the end of the
value, octal by typing “:8” or binary by typing “:2.” The result of the operation is displayed
in hex, decimal, octal, and binary.
Definition:
sub number1 number2
ERRORS AND SCREEN MESSAGES
Most commands return an explanatory message for misspelled or mistyped commands,
missing arguments, or invalid values.
Tab le 8 -5 lists errors that can be attributed to other
causes, especially errors that indicate a problem in the nonvolatile memory configuration.
Some errors can be resolved by contacting Emerson Network Power, Embedded Comput-
ing Technical Support at http://www.emersonembeddedcomputing.com/contact/postsa-
lessupport.html on the internet or send e-mail to support@artesyncp.com.
Table 8-5: Error and Screen Messages
Message: Source and Suggested Solution:
Error while clearing NV memory
Error while reading NV memory
Error while storing NV memory
NV memory has become corrupted. Use the nvinit
command to restore defaults.
1
Hit ‘H’ to skip auto-boot Consult the introduction to this chapter for information
about power-up conditions.