Emerson PME1 Network Router User Manual


 
TDM Interface: Front Panel I/O
10002367-02 PmT1 and PmE1 User’s Manual
6-9
The recommended cable assembly (Emerson part number C308A009-05) for P1 and P2 is
shown in
Fig. 6-4. The manufacturer part numbers for these connectors are Stewart Connec-
tor Systems SS-310808-5 and SS-800810-040-250. See
Ta bl e 6 -8 for the Compu-Shield and
RJ-45 jack pin assignments.
Figure 6-4: Front Panel I/O Cable Assembly (C308A009-05)
Table 6-8: Compu-Shield to RJ45 Pin Assignments
Caution: To reduce risk of fire, use only number 26 AWG or larger telecommunication line cord.
P1 and P2
Pin (signal)
:
Compu-Shield
Pin
1
:
1. This is a straight-through cable, there is no crossover.
RJ-45 Jack
Pin (signal)
:
——1 (no connect)
1 (RRING) 8 2 (RRING)
2 (RTIP) 7 3 (RTIP)
364
4 (TRING) 5 5 (TRING)
5 (TTIP) 4 6 (TTIP)
637
728
819
——
10 (no connect)
COMPU-SHIELD
8-pin Male
Modular Plug
Connector
8-pin Female
Modular Jack
Connector
!