Emerson PME1 Network Router User Manual


 
Regulatory Agency Warnings & Notices (continued)
PmT1 and PmE1 User’s Manual 10002367-02
ii
This board is designed to be connected to the telephone network or premises wiring using
a compatible modular jack which is Part 68 compliant. This board cannot be used on tele-
phone company-provided coin service. Connection to Party Line Service is subject to state
tariffs.
If this board causes harm to the telephone network, the telephone company will notify you
in advance that temporary discontinuance of service may be required. If advance notice is
not practical, the telephone company will notify the customer as soon as possible. Also, you
will be advised of your right to file a complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations, or pro-
cedures that could affect the operation of the equipment. If this happens, the telephone
company will provide advance notice in order for you to make the necessary modifications
in order to maintain uninterrupted service.
It is recommended that the customer install an AC surge arrestor in the AC outlet to which
this device is connected. This is to avoid damaging the equipment caused by local lighten-
ing strikes and other electrical surges.
The following table lists each applicable Facility Interface Code (FIC) along with the Service
Order Code (SOC) and connector jack type for the PmT1 and PmE1.
Note: The following information and instructions must be given to the final assembler/end user.
The mounting of the PmT1 and PmE1 in the final assembly must be made so that the PmT1
and PmE1 is isolated from exposure to hazardous voltages within the assembly. Adequate
separation and restraint of cables and cords must be provided.
The circuitry from the PmT1 and PmE1 to the telephone line must be provided in wiring
that carries no other circuitry that is specifically allowed in the rules, such as PR and PC
leads.
PC board traces carrying tip and ring leads shall have sufficient spacing to avoid surge
breakdown.
Board Name:
Facility Interface
Code (FIC):
FIC
Description:
Service Order
Code (SOC):
Jack
Type:
PmT1 and PmE1 04DU9.BN
04DU9.DN
04DU9.1KN
04DU9.1SN
1.54 Mbps AMI Superframe Format (SF) without
line power
1.544 Mbps SF and B8ZF without line power
1.544 Mbps AMI ESF without line power
1.544 Mbps AMI ESF and B8ZS without line power
6.0N
a
a. Combinations of equipment provide full protection to digital service. Billing protection and encoded analog protection are provided
either by including auxiliary equipment within the registration envelope or by use of a separately registered device.
RJ48C