Emerson PME1 Network Router User Manual


 
Monitor: Start-up Display
PmT1 and PmE1 User’s Manual 10002367-02
8-4
START-UP DISPLAY
At power-up or after a reset, the monitor runs diagnostics and reports the results in the
start-up display. The PmT1 and PmE1 displays have identical diagnostic reports.
Figure 8-1: Monitor Start-up Display
Note: The results of the power-up diagnostic tests are displayed at power-up or after a reset. A failed memory test
could indicate a hardware malfunction that should be reported to our Technical Support department at
http://www.emersonembeddedcomputing.com/contact/postsalessupport.htm on the internet or send e-
mail to support@artesyncp.com.
At power-up and reset, the monitor configures the board according to the contents of non-
volatile configuration memory. If the configuration indicates that an autoboot device has
been selected, the monitor attempts to load an application program from the specified
device. You can prevent the board from booting the OS if any of the power-up tests fail by
setting the NVRAM configuration parameter HaltOnFailure (see
Tab le 8 -1 and page 8-13).
Hardware
initialization
and power-up
diagnostic
reports
Monitor
command
prompt
Hello World !!!!!!!!!!!!!
MPC860 and SMC are initialized
Memory Size is 0x00400000
860 Decrementer Test PASSED
860 Time Base Timer Test PASSED
Print Hex Test, should = 89ABCDEF ? 89ABCDEF
Power Up Memory Test
Memory Test at 0x00040000 PASSED
Address Boundary Clear PASSED
All Memory Address Test ********
PASSED
BSS Zeroed
Data Section Relocated
Exception Vector Table Set to 0x0
Stack has been initialized to 0x10000 - 8
Monitor Cold Started
Power Up EEPROM Test PASSED
MPC860 Power Up Cache Test PASSED
PCI Bus Interface Initialized
Copyright Artesyn Communication Products, Inc., 2001
Created: Thu Jan 11 13:04:24 2001
===========
===========
=== ===
=== === ======
=== === ======
=========== ==
=========== === === == ==
=== ==== ==== == ===
=== ========== == ==
=== == == == == ==
=== == == == ==
PM/T1[Rev 2.6]
PM/Link (TM) Debug Monitor
Artesyn Communication Products,Inc.
Version Rev 2.6