Monitor: Monitor Function Reference
10002367-02 PmT1 and PmE1 User’s Manual
8-29
MONITOR FUNCTION REFERENCE
The PmT1 and PmE1 monitor functions fall into three groups: PmT1 and PmE1-specific
monitor functions, processor-specific functions, and standard Emerson monitor functions.
In order to save space, associated functions have been combined in groups under a single
function name. If you are looking for a function that is not listed by name in the following
sections, refer to the index to locate the desired information.
The functions require spaces between the function name and its arguments. No parenthe-
ses or other punctuation is necessary.
Example:
=>display a0000000
=>ConnectHandler f8 1000
No help for ___ The topic for help was misspelled or is not available.
Check the spelling. If the topic was a command name, use
the help command to check the spelling of the command.
You must use the full command name, not an
abbreviation.
Power-up Memory Test FAILED A failed memory test could mean a hardware
malfunction.
1
Unknown boot device The boot device is invalid. Use nvdisplay to check and edit
the ‘BootParams’ group, BootDev field. Save a new value
with nvupdate.
Unexpected _____ Exception at _____ There are many possible sources for this error.
If the error is displayed during boot, it could mean that
autoboot is enabled and invalid parameters are being
used.
If the error is displayed at reset or power-up and autoboot
is not enabled, report the error to Emerson Customer
Support.
If the error is displayed after a command has been
executed, an attempt to perform an operation that
causes an exception has probably been made.
Warning NV memory board
initialization skipped
Only minimum configuration has been completed. The
configuration data structures are invalid.
Warning NV memory is invalid - using
defaults
Consult the introduction to this chapter for information
about reset conditions.
1. Contact/report the error to Emerson Network Power Customer Support at
http://www.emersonembeddedcomputing.com/contact/postsalessupport.html on the Internet or
send e-mail to support@artesyncp.com.
Message: Source and Suggested Solution: