Fujitsu TX200 Server User Manual


 
213
PRIMERGY TX200 S2 User’s Guide
Installing hardware options
7
5 Install a dummy unit or a new hard disk unit.
6 Attach the hard disk cover.
7.6.5 Replacing the Failed Internal Hard Disk Unit
When an array system is configured with this server, a failed hard disk unit can be replaced and the
restoration can be performed without turning off the server and peripheral devices (hot swappable/hot
pluggable). For array systems, refer to "PRIMERGY ServerBooks" supplied with the server, and
"Supplement" supplied with options.
Perform the replacement as follows:
1 Open the hard disk cover.
2 Locate the failed hard disk unit by checking the hard disk failure LED of each
bay.
3 Pull out the failed hard disk unit a little towards you.
4 Wait for approximately 60 seconds (until the hard disk stops rotating) and pull
out the failed hard disk unit.
5 Insert a new hard disk unit.
6 Execute "Rebuild" or "Make Standby".
"Rebuild" or "Make Standby" may be executed automatically after hard disk unit replacement.
This can be checked from the status of the hard disk failure LED.