Fujitsu TX200 Server User Manual


 
256
Chapter 8 Configuring Hardware and Utilities
8.3.5 Adapter Properties
Detailed configuration information of SCSI adapters on the SCSI bus is set. Press the [F2] key from the
[Main] menu window, select [Adapter] and press the [Enter] key to display the window.
table: Items on the Adapter Properties Window
Item Setting Description
Host SCSI ID 7 (Fixed parameter) Specifies the SCSI ID of the SCSI controller.
SCSI Bus Scan Order Low to High (0..Max)
(Fixed parameter)
Specifies the SCSI bus scan order during the
startup.
Removable Media Support None (Fixed parameter) Sets whether or not the SCSI BIOS supports
removable disk units such as MO drives.
CHS Mapping SCSI Plug and Play
Mapping (Fixed parameter)
Specifies the disk mapping method.
Spinup Delay (Secs) 2 (at the time of
purchase)
1–15
Specifies the interval between a server startup and
the start of disk rotation.
Secondary Cluster Server No (Fixed parameter) Sets whether to enable or disable the secondary
cluster server.
Termination Control Auto (Fixed parameter) Sets whether to enable or disable the terminator on
the system board.
Restore Defaults Reads default values for the controller.
LSI Logic MPT SCSI Setup Utility Version MPT BIOS-IME-n.nn.nn
Adapter Properties
Adapter PCI DEV/
Bus Func
1020/1030 2 40
1020/1030 2 41
<Device Properties>
<RAID Properties><Synchronize Whole Mirror>
F1 =HELP
Esc=Abort/Exit
ArrowKeys=Select Item
Home/End=Select Item
-/+ =Change [Item]
Enter=Excute <Item>
Host SCSI ID
SCSI Bus Scan Order
Removable Media Support
CHS Mapping
Spinup Delay(Secs)
Secondary Cluster Server
Termination Control
<Restore Defaults>
[ 7]
[Low to High(0..Max)]
[None]
[SCSI Plug and Play Mapping]
[ 2]
[No]
[Auto]