Fujitsu TX200 Server User Manual


 
249
PRIMERGY TX200 S2 User’s Guide
8
Configuring Hardware and utilities
Console Redirection Submenu
This submenu configures detailed settings for console redirection.
RomPilot Submenu
The RomPilot is a remote console BIOS extended function.
This server cannot use this.
table: Items on the Console Redirection Menu
Item Setting Description
Console Redirection Disabled (at the time of
purchase)
Enabled
Sets whether to enable or disable console redirection.
When set to [Enabled] the following parameters
appear. Set each of them. If set to [Disabled], the
items are not displayed.
Port Serial1 (at the time of
purchase)
Serial2
Sets the serial port to be used for console redirection.
Media Type Serial (at the time of
purchase)
•LAN
Sets the connection type for console redirection.
Baud Rate 1200
•2400
•4800
9600 (at the time of
purchase)
19.2K
38.4K
57.6K
•115.2K
Sets the speed of the console redirection connection
(in bps).
Protocol VT100
VT100,8bit
PC-ANSI,7bit
PC-ANSI
VT100+ (at the time of
purchase)
Sets the console type for console redirection.
Flow Control None
XON/XOFF
CTS/RTS (at the time of
purchase)
Sets flow control for console redirection.
Mode Standard
Enhanced (at the time of
purchase)
Sets the range of use for console redirection.
table: Item on the RomPilot Menu
Item Setting Description
RomPilot Support Disabled (Fixed parameter) Sets whether or not to use RomPilot.