Fujitsu TX200 Server User Manual


 
271
PRIMERGY TX200 S2 User’s Guide
9
Operation and Maintenance
System Management Configuration changed The hardware configuration changed or is invalid. If this is
displayed right after changing the hardware configuration,
disregard it. If the same message is displayed again, check the
cable connections, and then select [Yes] for the [Reset
Configuration Data] setting under the [Advanced] menu of the
BIOS Setup Utility. If the message still appears, refer to
"Contact Information" in "Start Guide", and contact your
maintenance engineer.
Invalid System Configuration Data The system configuration is invalid. Select [Yes] for the [Reset
Configuration Data] setting under the [Advanced] menu of the
BIOS Setup Utility.
Invalid System Configuration Data - run
configuration utility
The system chassis has been opened. The hard disk cover or side cover is open. Close the cover.
The system performed an emergency
shutdown.
The system shut down due to some reason; refer to the event
log for details.
Manually-operated Retention Latch is not
closed at Hot-Plug PCI slot n
The baseboard is abnormal.
It must be replaced. Refer to "Contact Information" in "Start
Guide", and contact your maintenance engineer.
CNR Plug and Play EEPROM contents are
damaged.
A CNR error.
CNR version newer than motherboard, some
CNR functionality may be lost.
CNR and AC97 Version do not match, AC97
functionality of CNR ignored.
Illegal AC97 configuration, AC97 Audio and
Modem functions disabled.
Illegal AC97 configuration, AC97 Modem
function disabled.
CNR LAN Interface not compatible with
Motherboard, LAN function disabled.
USB version required by the CNR is not
supported by the motherboard. The CNR USB
functions will operate at lower spe
CNR EEPROM PCI Configuration data size
mismatch
BIOS update for installed CPU failed Check that the correct CPUs are installed. If the correct CPU is
installed and the message is displayed, select [Yes] for the
[Reset Configuration Data] setting under the [Advanced] menu
of the BIOS Setup Utility. If the message still appears, the CPU
or baseboard must be replaced. Refer to "Contact Information"
in "Start Guide", and contact your maintenance engineer.
Patch for installed CPU not loaded. Please run
the bios flash update diskette.
CPU ID n failed CPU ID n is abnormal (where "n" represents the CPU number).
Select [Disabled] for the [CPU Status] setting under the
[Server] menu of the BIOS Setup Utility. Afterwards, replace
the faulty CPU.
Invalid NVRAM media type The NVRAM is abnormal.
Power off the server and turn it back on. If the message still
appears, the keyboard must be replaced. Refer to "Contact
Information" in "Start Guide", and contact your maintenance
engineer.
Missing or invalid NVRAM token
table: List of POST Errors
Message Description