MAGNUM 6K SWITCHES, MNS-6K USER GUIDE
speed – specifically sets the speed to be 10 or 100Mbps. Note – this works only with
10/100 ports – with 10Mbps ports, the option is ignored. No error is shown. See speed
settings section below.
flow – sets up flow control on the port. See Flow Control section below
bp – back pressure – enables back pressure signaling for traffic congestion management
status – disable – disables the port from operation
Syntax show port[=<port number>]
In the example listed below, the ports 11 and 12 are given specific names. Ports 9 and 13
are active, as shown by the link status. Port 13 is set to 100 Mbps – all other ports are set
to 10Mbps. All ports are set with auto sensing (speed)
Magnum6K25# device
Magnum6K25(device)## setport port=11 name=JohnDoe
Magnum6K25(device)## setport port=12 name=JaneDoe
Magnum6K25(device)## show port
Keys: E = Enable D = Disable
H = Half Duplex F = Full Duplex
M = Multiple VLANs NA = Not Applicable
LI = Listening LE = Learning
F = Forwarding B = Blocking
Port Name Status Dplx Media Link Speed Part Auto Vlan GVRP STP
-------------------------------------------------------------------------------------------------------------
9 B1 E H 10Tx UP 10 No E 1 - -
10 B2 E H 10Tx DOWN 10 No E 1 - -
11 JohnDoe E H 10Tx DOWN 10 No E 1 - -
12 JaneDoe E H 10Tx DOWN 10 No E 1 - -
13 B5 E F 100Tx UP 100 No E 1 - -
14 B6 E H 10Tx DOWN 10 No E 1 - -
15 B7 E H 10Tx DOWN 10 No E 1 - -
16 B8 E H 10Tx DOWN 10 No E 1 - -
Magnum6K25(device)## exit
Magnum6K25#
FIGURE 75 – Port setup
The port’s speed and duplex (data transfer operation) setting are summarized below.
Speed settings
Auto (default) – Senses speed and negotiates with the port at the other end of the link
for data transfer operation (half-duplex or full-duplex). “Auto” uses the IEEE 802.3u
auto negotiation standard for 100Base-T networks. If the other device does not comply
124