HP (Hewlett-Packard) RX3600 Computer Accessories User Manual


 
Table B-5 SAS cable part numbers (continued)
Option kit part numberType of cableApproximate cable length
432239-B21Mini SAS 4x to mini SAS 4x6 m (20 ft.)
419537-B21Mini SAS 4x to standard SAS 4x
Completing the Adapter Installation
Procedure B-28 Updating the Firmware
To update the firmware on the server, controller, or hard drives, use Smart Components. These
components are available on the Firmware Maintenance CD. A more recent version of a particular
server or controller component might be available on the support page of the HP website
(http://www.hp.com/support).
1. Find the most recent version of the component that you require. Components for controller
firmware updates are available in offline and online formats
2. Follow the instructions for installing the component on the server. These instructions are
given with the CD and are provided on the same Web page as the component.
3. Follow the additional instructions that describe how to use the component to flash the ROM.
These instructions are provided with each component.
Installing device drivers and Management Agents
The drivers for the controller are bundled into the supported Red Hat and Novell Linux
distributions.
In a system that does not yet have Linux installed:
1. Follow the standard controller installation procedure.
2. Reboot the server.
3. Follow the standard procedure for installing Linux. As Linux is installed, it recognizes the
controller and automatically loads the correct driver.
4.
In a system that already has Linux installed:
1. Power down the system.
2. Follow the standard controller installation procedure.
3. Power up the system. As Linux boots, it recognizes the controller.
4. Enter one of the following commands as appropriate to ensure that the driver is loaded
correctly:
Red Hat #mkinitrd -f /boot/efi/efi/redhat/initrd-$(uname
-r).img $(uname -r)
Novell (SLES) #mkinitrd -k /boot/vmlinux -i/boot/initrd
5. For Novell, enter the following command to confirm that the driver is active:
#lsmod | grep cciss
If the driver is active, the system responds by displaying cciss.
Installing Management Agents The most recent versions of the agents are available on the
support page of the HP website (http://www.hp.com/support/itaniumservers). For
installation instructions, refer to the downloadable file HP Insight Management Agents for Linux
on Integrity Servers provided with the agents. If the new agents do not function correctly, you
might also need to update Systems Insight Manager. The latest version of Systems Insight Manager
is available for download at the HP website (http://www.hp.com/servers/manage).
Processor Upgrades
The HP Integrity rx2660, rx3600, rx6600 servers, and BL860c server blade support upgrades from
Intel® Itanium® Montecito to Intel® Itanium® Montvale processors.
Processor Upgrades 279