Table 2-5 Environmental Specifications (system processing unit with hard disk)
ValueParameter
+5˚ C to +35˚ C (+41˚ F to +95˚ F)Operating temperature
- 40˚ C to +70˚ C (-40˚ F to +158˚ F)Storage temperature
+40˚ C (+104˚ F)Over-temperature shutdown
15% to 80% relative (noncondensing)Operating humidity
90% relative (noncondensing) at + 65˚ CStorage humidity
Acoustic Noise Emission (ISO 9296)
LwAd =7.3BSound Power Level
1
LpAm =57.1dBSound Pressure Level
Altitude
0 to 3000 m (10,000 ft.) maxOperating altitude
0 to 4572 m (15,000 ft.) maxStorage altitude
1 Typical configuration at room temperature (25˚C).
Table 2-6 Physical and Environmental Specifications
Overall System
Dimensions
(W X D X H)
Weight
Condition
Airflow, Maximun at
35ºC
1
Airflow,
Nominal
Typical Heat
Release
PedestalRackPedestalRackServer
Voltage
200-240
V ac
Voltage
100-127
V ac
69.2 cm
(27.2
in.) x
36.9 cm
(14.5
in.) x
51.2 cm
(20.2
in.)
69.6
cm
(27.4
in.) x
44 cm
(17.32
in.) x
17.24
cm
(6.8
in.)
10.9
kg (24
lbs.)
Max:
45.36
kg. (100
lbs.)
75-90
lbs.
m³/hr
2
CFMm³/hr
2
CFMWattsWattsDescription
44.9
kg.
(99
lbs.)
371218294173669432Minimum
Configuration
51.7
kg.
(114
lbs.)
37121829417310561095Maximum
Configuration
371218294173669685Typical
Configuration
(1x) Itanium 1.8G/24M CPU, (4x) 4GB
DDRII DIMM memory, (0x) SAS Hard
Drives, (0x) PCI/PCI-X/PCIe added to
public I/O cards.
Minimum
Configuration
Air Flow Diagram Cooling Scheme (F - R)
Front to Rear (F-R)
ASHRAE
Class 1
(2x) 1.8G/24M CPUs, (24x) 4GB DDRII
DIMM memory, (8x) SAS Hard Drives,
(8x) PCI/PCI-X/PCIe added to public I/O
cards.
Maximum
Configuration
Half-loaded configuration: (1x) Itanium
1.8G/24M CPUs, (12x) 4GB DDRII DIMM
memory, (4x) SAS Hard Drives, (4x)
PCI/PCI-X/PCIe added to public I/O cards.
Typical
Configuration
50 System Specifications