HP (Hewlett-Packard) RX3600 Computer Accessories User Manual


 
Flashing BIOS and EFI Driver on the First Controller
To update the EFI driver on the first controller, follow these steps:
1. At the fsO:\> prompt, enter mptutil -o -g <Bios_File> <EFI_driver_file>
-c 0.
2. At the fsO:\> prompt, enter reset.
The filename is optional and you are prompted for a filename if omitted.
Common Questions About Flashing Firmware
Question After I update firmware on my SAS HBA, why doesn't the version string change
in the menu?
Answer The firmware you just flashed on the HBA does not run until a diagnostic reset
occurs. If you exit the utility and reenter it, the version string is updated.
Question
This image does not contain a valid nvdata when I try to flash the firmware, why?
Answer
You are expected to concatenate a proper nvdata image on to the firmware.
mptutil keeps you from flashing an image without one. To concatenate nvdata
and firmware you need to run the mptutil -o -d
64it__l.fw,sas106x.dat,output.fw command. .
64it__l.fw is the firmware image without a nvdata image
sas106x.dat is the nvdata image. This file depends on the type/rev of HBA
on which the firmware is used
output.fw is the name of the file created with the firmware and nvdata
concatenated. This concatenated image can be used for all boards of this type
or revision.
Question How do I program multiple cards in a system from the command line?
Answer
mptutil (EFI) does not support this.
Question Can I program a new flash and option ROM in the same command line argument?
Answer
Yes. Run the mptutil -f <firmware_name> -b <option_rom_name>
command.
Viewing the VPD Information for EFI Driver and RISC Firmware
To view the VPD information for the EFI driver and RISC firmware, follow these steps:
At the fsO:\> prompt, enter mptutil -o -vpd -c 0.
EFI Commands
To configure an Integrated Mirror (IM) Array on the SAS Controller, use one of the following
EFI commands:
DRVCFG (GUI interface)
CFGGEN (command line interface)
NOTE: If you are not using the IM functionality, do not follow these procedures.
DRVCFG Utility
To configure an IM on the SAS controller, follow these steps:
Starting the DRVCFG Utility
To start theDRVCFGconfiguration utility, follow these steps:
1. Select the EFI Shell from the console menu.
2. Type drvcfg -s and press Enter.
HP 8 Internal Port SAS HBA (SAS Controller) 285