Figure 3-2 Removing and Replacing the Memory Carrier Assembly Cover
Replacing the Memory Carrier Assembly Cover
To replace the memory carrier assembly cover, follow these steps:
1. Position the cover onto the opening above the memory carrier assembly.
2. Slide the cover toward the right side of the server until it is flush with the center chassis
wall; push firmly.
3. Slide the top cover forward until it is flush with the front of the chassis.
4. Push the cover release lever down into the latched position (Figure 3-1).
5. Lock the cover release lever by turning the cam 90 degrees clockwise.
Installing a Hot-Swappable Power Supply
The server can have one or two hot-swappable power supplies. These power supplies are located
at the rear of the server. The supported configuration of the server requires a minimum of one
power supply. You can install or replace a hot-swappable power supply using the procedures
in this section when power is on or off.
CAUTION: Observe all ESD safety precautions before attempting this procedure. Failure to
follow ESD safety precautions can result in damage to the server.
NOTE: A hot-swappable device does not require interaction with the operating system before
the device is removed from or installed into the server.
The dc power to the server does not have to be off to install or replace a hot-swappable power
supply.
Power Supply Loading Guidelines
The supported configuration of the server requires a minimum of one power supply installed
in either slot P0 or slot P1. You can install a second, optional hot-swappable power supply to
provide 1+1 capability. The left side (viewed from the rear of the chassis) hot-swappable power