PHY Properties Screen
The PHY Properties screen enables you to view and modify PHY specific settings. To access PHY
Properties, press Enter on the PHY Properties field from the Advanced Adaptor Properties
screen.
You can perform the following actions from PHY Properties:.
To display the next PHY, press N.
To display the previous PHY, press P.
To reset the Link Error Counts for this PHY or all PHYs, press Enter on Reset Link Error
Counts. Resetting Link Error Counts issues a PHY Link Error Reset. The following prompt
displays when you press Enter:
Are you sure you want to reset Phy error counts?
Reset error counts for this Phy only
Reset error counts for all Phys
Cancel
NOTE: The Link Error Settings values on this screen display the current values for this PHY
only, and are not modifiable. To modify the Threshold values, you must return to Advanced
Adapter Properties screen.
PHY Displays the PHY number current information.
SAS Port Indicates the associated SAS Port (0 to N) as configured on this
adapter.
Link Status Indicates the PHY link status. Possible values are:
Enabled, Unknown Link Rate
PHY Disabled
Enabled, negotiation failed
Enabled, SATA OOB Complete
Enabled, 1.5 Gbs
Enabled, 3.0 Gbs
Discovery Status 32 bit hexidecimal value indicating the discovery status for the PHY
or Expander. Currently defined values are:
Discovery completed successfully - 0x00000000
Loop Detected - 0x00000001
Unaddressable device exists - 0x00000002
Multiple Ports - 0x00000004
Expander Error - 0x00000008
SMP Timeout - 0x00000010
Out of route entries - 0x00000020
SMP Response Index Does Not Exist - 0x00000040
SMP Response Function Failed - 0x00000080
SMP CRC error - 0x00000100
Device Identifier Indicates the ASCII device identifier string extracted from the
device's Inquiry Data.
Scan Order Indicates the scan order for this device (equivalent of a SCSI ID for
parallel SCSI).
Device Information Indicates if a device is SAS.
SAS Address Indicates the SAS Address of this device.
Link Error Setting Invalid DWORDs - Number of invalid dwords that have been
received outside of PHY reset sequences, since the last PHY
Link Error Reset.
a
Loss of DWORD Sync - Number of times, since the last PHY
Link Error Reset, that dword synchronization was lost and the
link reset sequence occurred.
a
298 Core I/O Card Utilities