Intel IXF1104 Computer Hardware User Manual


 
Intel
®
IXF1104 4-Port Gigabit Ethernet Media Access Controller
217 Datasheet
Document Number: 278757
Revision Number: 009
Revision Date: 27-Oct-2005
15 Rx_parity_sense Port 3
SPHY Mode:
Indicates the parity sense to check the parity on
RDAT bus for port 3.
0 = Odd Parity
1 = Even Parity
MPHY Mode:
NA
R/W 0x0
14 Rx_parity_sense Port 2
SPHY Mode:
Indicates the parity sense to check the parity on
RDAT bus for port 2.
0 = Odd Parity
1 = Even Parity
MPHY Mode:
NA
R/W 0x0
13 Rx_parity_sense Port 1
SPHY Mode:
Indicates the parity sense to check the parity on
RDAT bus for port 1.
0 = Odd Parity
1 = Even Parity
MPHY Mode:
NA
R/W 0x0
12 Rx_parity_sense Port 0
SPHY Mode:
Indicates the parity sense to check the parity on
RDAT bus for port 0.
0 = Odd Parity
1 = Even Parity
MPHY Mode:
Indicates the parity sense to check the parity on
RDAT bus for all ports.
0 = Odd Parity
1 = Even Parity
R/W 0x0
11
Rx_port_enable
Port 3
SPHY Mode:
0 = Disables the selected SPI3 RX port.
1 = Enables the selected SPI3 RX port.
MPHY Mode:
0 = Disables the selected SPI3 RX port.
1 = Enables the selected SPI3 RX port.
R/W 0x1
10
Rx_port_enable
Port 2
SPHY Mode:
0 = Disables the selected SPI3 RX port.
1 = Enables the selected SPI3 RX port.
MPHY Mode:
0 = Disables the selected SPI3 RX port.
1 = Enables the selected SPI3 RX port.
R/W 0x1
Table 147. SPI3 Receive Configuration ($0x701) (Continued) (Sheet 3 of 4)
Bit Name Description Type
1
Default
1. RO = Read Only, No clear on Read; R = Read, Clear on Read; W = Write only; R/W = Read/Write, No
clear; R/W/C = Read/Write, Clear on Write