Configuring WAN Access
Configuring inbound calls
MAX 6000/3000 Network Configuration Guide 3-65
• Unspecified Max HDLC=0
• Unspecified Max V110=0
Limiting all calls that do not specify a DNIS number
To specify that the MAX unit accepts twenty calls, of any type, that do not specify a DNIS
number, set the following parameters as shown:
• Unspecified Max Calls=20
• Unspecified Max Modem=20
• Unspecified Max HDLC=20
• Unspecified Max V110=20
Limiting V.110 calls to a specific DNIS number
To specify that the MAX unit accepts fifteen simultaneous V.110 calls that specify a DNIS
number of 1212 and allows 100 simultaneous calls to any DNIS number except 1212, set the
following parameters as shown:
• DNIS #1 Max Calls=15
• DNIS #1 Modem=0
• DNIS #1 HDLC=0
• DNIS #1 V110=15
• Unspecified Max Calls=100
• Unspecified Modem Calls=100
• Unspecified HDLC Calls=0
• Unspecified V110 Calls=0