Lucent Technologies 6000 Network Router User Manual


 
Configuring Individual WAN Connections
Configuring MP, MP+ and BACP connections
MAX 6000/3000 Network Configuration Guide 4-51
Following is a comparable RADIUS profile:
fred Password = "localpw"
Service-Type = Framed-User,
Framed-Protocol = MP,
Framed-IP-Address = 10.10.1.2,
Framed-IP-Netmask = 255.255.255.255,
Ascend-Base-Channel-Count = 2,
Ascend-Maximum-Channels = 2
Example of a MP connection with BACP
To configure a MP connection that uses BACP:
1 Open the Answer profile.
2 Enable PPP and MP encapsulation and specify the appropriate routing, bridging, and
authentication values. For example:
Ethernet
Answer
Encaps
MP=Yes
PPP=Yes
PPP Options
Route IP=Yes
Route IPX=Yes
Bridge=Yes
Recv Auth=Either
3 Enable BACP to monitor bandwidth requirements on the basis of received packets:
BACP=Yes
4 Exit the profile and, at the exit prompt, select the exit and accept option.
5 Open a Connection profile, specify the name of the remote device, and activate the profile.
For example:
Ethernet
Connections
chloe
Station=chloe
Active=Yes
6 Select MP encapsulation and set the MP authentication options. For example:
Encaps=MP
Encaps Options
Send Auth=PAP
Send PW=remotepw
Aux Send PW=N/A
Recv PW=localpw
7 Enable BACP to monitor bandwidth requirements for packets transmitted on this
connection, and configure the Lucent criteria for bandwidth management. For example:
BACP=Yes
Base Ch Count=1
Min Ch Count=1
Max Ch Count=2
Inc Ch Count=1