Lucent Technologies 6000 Network Router User Manual


 
Setting Up Virtual Private Networks
Configuring ATMP tunnels
MAX 6000/3000 Network Configuration Guide 11-17
Type=Gateway
Password=private
SAP Reply=No
UDP Port=5150
GRE MTU=1472
Force fragmentation=No
Idle limit=0
ATMP SNMP Traps=No
The IP routing connection to the Foreign Agent uses the following parameters (shown with
sample settings):
Ethernet
Connections
any Connection profile
Station=foreign-agent
Active=Yes
Encaps=MPP
Dial #=555-1213
Route IP=Yes
Encaps options...
Send Auth=CHAP
Recv PW=foreign-pw
Send PW=home-pw
IP options...
LAN Adrs=10.65.212.226/24
Or comparable settings in a RADIUS profile:
mclient Password = "local-password"
Service-Type = Framed-User,
Tunnel-Type = ATMP,
Tunnel-Server-Endpoint = "2.2.2.2:1234",
Tunnel-Password = "tunnel-password",
Tunnel-Private-Group-ID = "home-router"
The nailed connection to the home network uses the following parameters (shown with sample
settings):
Ethernet
Connections
any Connection profile
Station=homenet
Active=Yes
Encaps=MPP
Dial #=N/A
Calling #=N/A
Route IP=Yes
Route IPX=Yes
IP options...
LAN Adrs=5.9.8.2/24