Configuring Individual WAN Connections
Configuring ARA connections
MAX 6000/3000 Network Configuration Guide 4-75
Configuring ARA connections
ARA uses V.42 Alternate Procedure as its data link, so ARA can be used only over
asynchronous modem connections.
Example of an ARA configuration
To configure ARA connections, you set the following parameters (shown with sample
settings):
Ethernet
Mod Config
Appletalk=Yes
AppleTalk
Zone Name=*
Ethernet
Answer
Profile Reqd=Yes
Encaps
ARA=Yes
Ethernet
Connections
Encaps=ARA
Encaps Options
Password=*SECURE*
Max. Time (min)=0
AppleTalk Options
Peer=Dialin
Zone Name=
AppleTalk Router=Seed
Net Start=300
Net End=309
Default Zone=
Zone Name #1=
Zone Name #2=
Zone Name #3=
Zone Name #4=
Example of ARA configuration that enables IP access
This section shows an example of an ARA configuration that enables a Macintosh with an
internal modem to dial into the MAX unit by means of ARA Client software and communicate
with an IP host on the Ethernet. A connection that does not require IP access would be a subset
of this example. Figure 4-12 shows the sample network.