Lucent Technologies 6000 Network Router User Manual


 
Configuring X.25
Setting up X.25 PAD sessions
MAX 6000/3000 Network Configuration Guide 6-21
The Listen command specifies the match pattern for accepting an incoming call. It uses
the following syntax:
The MAX matches the address argument against the subaddress specified by the
incoming call. If the subaddresses match, the MAX accepts the incoming call.
The MAX matches the data against the last 12 bytes of the user data field of
incoming calls. If the data matches, the MAX accepts the incoming call.
r
eset
The Reset command resets a virtual circuit by generating a Reset-Request packet with 0
cause (DTE originated) and 0 diagnostic.
s
tatus
The Status command requests the status of a virtual call placed to a remote DTE.
PAD service signals
The PAD acknowledges commands and informs the user about the internal state of the PAD by
transmitting PAD service signals to the terminal server. The terminal-server user can suppress
the reception of PAD service signals by setting PAD parameter #6 to 0. Table 6-4 lists the PAD
service signals.
Table 6-4. PAD service signals
Service signal Description
RESET DTE The remote DTE has reset the virtual circuit.
RESET ERR A reset has occurred because of a local procedure error.
RESET NC A reset has occurred because of network congestion.
COM A call has been connected.
PAD ID Precedes a string that identifies the PAD.
ERROR The terminal-server user used faulty syntax when entering an X.25/PAD
command.
CLR A virtual circuit has been cleared.
ENGAGED In response to the Status command, this signal indicates that a virtual
call is up.
FREE In response to the Status command, this signal indicates that a virtual
call has been cleared.
PAR with X.3
parameter
reference
numbers and
their current
values
This string is a response to the Set? command.