Lucent Technologies 6000 Network Router User Manual


 
3-42 MAX 6000/3000 Network Configuration Guide
Configuring WAN Access
Configuring Host/BRI lines
Enabling the device to make outbound calls
Jims setup is similar to Allys, but he needs to access the Internet, so you must configure the
MAX unit to enable outbound calls. Proceed as follows:
1 Open System > Sys Config and enable trunk groups systemwide.
2 Exit the profile and, at the exit prompt, select the exit and accept option.
3 Open a Net/T1 (or Net/E1) profile and make sure that some of the lines channels are
assigned to the same trunk group. Then, exit the profile and, at the exit prompt, select the
exit and accept option.
4 Open a System > Dial Plan profile.
5 Set the Data Service and PRI # Type parameters to Inherit.
6 Open a Host/BRI > Line Config > Line Config profile > Line N subprofile.
7 Set the Dial Plan parameter to Extended.
8 Exit the profile and, at the exit prompt, select the exit and accept option.
If the profiles you have configured are not the active Sys Config profiles and the active Line
Config profile, activate them as described in Activating a profile on page 2-7.
Example of configuring outbound calls
In this sample configuration, the terminating equipment on line 1 can make an outbound call
using trunk group 5 and Dial Plan profile 2. With this configuration, the caller at the Host/BRI
terminating equipment dials 502-408-555-1212 and connects to the device whose telephone
number is 408-555-1212 (trunk group 5, dial plan 2).
System
Sys Config
Use Trunk Grps=Yes
System
Dial Plan
Boston
Name=Boston
Call-by-Call=6
Data Svc=Inherit
PRI # Type=Inherit
Host/BRI
Line Config
local
Name=local
Line 1...
Enabled=Yes
Dial Plan=Extended
Ans 1#=1212
Ans 2#=