Lucent Technologies 6000 Network Router User Manual


 
Configuring WAN Access
Configuring MAXDAX
MAX 6000/3000 Network Configuration Guide 3-83
Routing calls on the basis of called number
Figure 3-5 shows an example of a MAXDAX installation.
Figure 3-5. Sample MAXDAX (T1) installation
On MAX 1, T1 Drop and Insert enables users connected to the PBX to make and receive calls.
The system administrator configures MAXDAX on MAX 2.
The system administrator uses Answer Plan profiles to direct incoming calls to the PRI line,
and therefore does not change any of the parameters in the Net/T1 > Line Config > Line Config
profile > Line N > Net2Net Incoming Calls profile from their default settings:
Net/T1
Line Config
Line Config profile
Line 1...
Net2Net Incoming Calls
Ch 1=Switched
Ch 1 Dest ChanGroup=1
Ch 1 Dial Plan #=0
Ch 1 #DialPlanSelDigits=2
Ch 2=Switched
Ch 2 Dest ChanGroup=1
Ch 2 Dial Plan #=0
Ch 2 #DialPlanSelDigits=2
Ch 3=Switched
Ch 3 Dest ChanGroup=0
Ch 3 Dial Plan #=0
Ch 3 #DialPlanSelDigits=0
To reach Video System C, a user dials the number (617) 555-1212. MAX 2 should only
redirect to the PRI line any calls received with a called number of 6175551212. The system
administrator configures the Answer Plan profile as follows:
Leased T1
PBX
PSTN
Pipeline 75
Video System A
T1
PRI
Video System C
Serial line
MAX 1 MAX 2
Video System B
Serial line