Lucent Technologies Comcode 108678723 Server User Manual


 
DEFINITY ECS Release 8.2 ATM Installation,
Upgrades, and Administration
555-233-124
Issue 1
April 2000
Administering ATM-PNC and ATM-CES
5-31Administering DEFINITY ECS
5
Field description:
Gain/Loss adjustments
Gain and loss are administrable. Calls between a digital (BRI or DCP) phone
(6400 and 8400 series) and an analog trunk port require adjustments to the
default gain/loss settings to prevent distortion. Use the procedure (Table 5-12
) to
administer digital phones on ATM-PNC DEFINITY ECSs.
NOTE:
Use the following procedure only for Series 6400 or 8400 digital phones.
Algorithm The name of the cache algorithm (default is lan). Possible values are
none, lan, man, wan, and custom.
When this field is changed to none, lan, man, or wan, the read-only For
Latency and Hold Time field values change to the following (all other
entries are blank):
Value For Latency (ms) Hold Time (ms)
none 00
lan 50 36
012
man 800 80
50 16
08
wan 800 200
200 36
50 16
00
When this field is custom, none of the For Latency or Hold Time field
values change, but the fields change from read-only to read/write. For
example, if you want a slight variation of the wan algorithm, type wan first
to set the above values, then type custom to change the individual
parameters.
Size The maximum number of entries simultaneously allowed in the cache
(default = 410).
For Latency These fields (10) are read-only if the Algorithm field is none, lan, man,
or wan, but are read/write if Algorithm is custom. Defaults: 36 for the
1st entry, 0 for the second, blank for the last 8 entries.