DEFINITY ECS Release 8.2 ATM Installation,
Upgrades, and Administration
555-233-124
Issue 1
April 2000
Troubleshooting
6-36Troubleshooting ATM-PNC
6
Screen 6-14. Error report
Screen 6-15
shows the screen output for the display errors
command.
Screen 6-15. Hardware error report—screen 9
In this example the errors that have
ATM-NTWK
for
Name
field and
1
for
Aux
Data
field indicate an error returned to the TN2305/TN2306 circuit
pack from the ATM network. In this case, the
Err Type
field shows the
cause code returned by the ATM network (see Table 6-11
). In the earlier
example, two cause codes (41 and 3) are reported from the ATM network.
For more information about these cause codes and repair information see
the ATM-NTWK (ATM Network Error) maintenance object.
display errors Page 1 of 1 SPE A
ERROR REPORT
The following options control which errors will be displayed.
ERROR TYPES
Error Type: Error List: errors
REPORT PERIOD
Interval: a From: / / : To: / / :
EQUIPMENT TYPE ( Choose only one, if any, of the following )
Cabinet:
Port Network:
Board Number:
Port:
Category: pnc
Extension:
Trunk ( group/member ): /
display errors Page 9 SPE A
HARDWARE ERROR REPORT
Port Mtce Alt Err Aux First Last Err Err Rt/ Al Ac
Name Name Type Data Occur Occur Cnt Rt Hr St
AT01A ATM-NTWK 41 1 11/12/16:59 12/09/15:10 14 0 0 n n
AT01A ATM-NTWK 31 0 11/13/18:27 11/20/20:02 5 0 0 n n
AT02A ATM-NTWK 0 0 11/13/18:45 11/13/18:45 1 0 0 n n
AT02A ATM-NTWK 31 0 11/15/14:40 11/15/14:41 2 120 0 n n
AT01B ATM-NTWK 31 0 11/16/17:39 11/16/17:39 1 0 0 n n
AT01A ATM-NTWK 3 1 11/16/18:19 11/26/13:13 12 0 0 n n