Troubleshooting
6-5Troubleshooting ATM-CES
6
Troubleshooting ATM-CES
Table 6-4 provides a first-level method for troubleshooting an installation.
The following list provides tips for further ATM-CES troubleshooting:
Inspecting LEDs—Describes the possible LED states on the
TN2305/TN2306 ATM interface circuit packs
—ATM switch
Troubleshooting interoperability—Provides guidelines for troubleshooting
Physical connections
Administration
TN2305/TN2306 circuit pack
ATM signaling architecture
Unusual ATM trouble conditions—Describes difficult-to-diagnose failure
modes in the DEFINITY ECS and ATM switch combinations.
DEFINITY ECS ATM-CES troubleshooting commands—Describes
specific troubleshooting commands.
Table 6-4. ATM-CES installation troubleshooting checklist
Problem Solution
Is DEFINITY ECS software Release 7 or
later?
Verify that software is Release 7 or later
On System Parameters Maintenance
screen
Is
Bus Bridge
field set to enabled? (csi)
Is
Packet Bus
field set to activated?
(r,si)
Are EI circuit packs TN570Bs or later?
Set to correct field
Set to correct field
Verify/replace EI circuit packs
All COR, COS, UDP, FRLs, AAR, and ARS
support proper routing
Verify they are all set correctly