Lucent Technologies Comcode 108678723 Server User Manual


 
DEFINITY ECS Release 8.2 ATM Installation,
Upgrades, and Administration
555-233-124
Issue 1
April 2000
Installing a DEFINITY ECS ATM-PNC
3-25Synchronization Installation and Testing
3
To configure the 316X CSU to send an AIS blue alarm, use the procedures in
Table 3-12
.
NOTE:
All four faceplate status LEDs on the DS1 circuit pack are dark (not lit) when
using an external CSU or DSU/CSU. The STATUS LEDs on the DS1 circuit
pack are only functional with a 120A ICSU.
Table 3-12. Configuring the 316X CSU to send AIS blue alarm
Step Action Description
1. Configure CSU At the 316X CSU press the double-up arrow
2. Go through the
readout steps
Press the button under “Cnfig.”
3. Continue Press the button under “Activ.”
4. Continue Press the button under “Edit.”
5. Continue Press the right arrow until “GEN” displays.
6. Continue Press the button under “GEN.”
7. Continue Press F1 (“Next”) until “Gen Yellow Alarm” displays. (This
option defaults as enabled.)
8. Continue Press the button under “Disabled.”
9. Continue Press the double-up arrow.
Save Option displays when “Enabled” changes to
“Disabled.”
10. Save settings Press the button under the word “Yes” at the “Save
Options Yes or No” prompt. Otherwise press F1 twice.
11. Save options Press the button under “Activ” when asked where to save
the options.
Command Complete displays.
12. Return to default
screen
The CSU times out to its default ESF CSU Operational
screen or set it there by pressing the double-up arrow
once and then pressing F1 twice.
13. Install the splitter
Go to Table 3-13 to install the splitter.