DEFINITY ECS Release 8.2 ATM Installation,
Upgrades, and Administration
555-233-124
Issue 1
April 2000
Installing a DEFINITY ECS ATM-PNC
3-8Synchronization Installation and Testing
3
Figure 3-3. 402A synchronization splitter
Figure Notes:
1. Amphenol connector to
DEFINITY ECS
2. Network timing connection
3. Timing alarm lead connection
4. Timing output ports (RJ45) to ATM switch
1
5. Jumpers and capacitors (inside case). See
Figure 3-5 for settings.
1. Ports J1 and J2 provide identical DS1 timing source signals to the ATM switches.
The ATM switch can use two separate DS1 timing signals (one at a time from two
separate spans).
402A
108508094
1
2
0
O
H
M
E
1
S
Y
N
C
S
P
L
IT
T
E
R
TO ATM SWITCH
NETWORK
ALARM
L
u
c
e
n
t
Te
c
h
n
o
lo
g
ie
s
crda402a KLC 020300
1
2
3
4
TO DEFINITY
5
5