Lucent Technologies Comcode 108678723 Server User Manual


 
DEFINITY ECS Release 8.2 ATM Installation,
Upgrades, and Administration
555-233-124
Issue 1
April 2000
Installing a DEFINITY ECS ATM-PNC
3-21Synchronization Installation and Testing
3
Connected through an ICSU.
Use the procedures in Table 3-9
to install the
splitter between an ICSU and a DS1 circuit pack.
Table 3-9. Installing the splitter through an ICSU
Step Action Command Description
1. Disable
synchronization
switch
disable
synchronization
-switch
Prevent the system from switching synchronization
sources.
2. Busyout DS1
circuit pack
busyout board
UUCSS
Busyout the designated DS1circuit pack.
3. Remove cable
from DS1 circuit
pack
Remove the existing H600-307 cable from the backplane
slot corresponding to the designated DS1 circuit pack.
4. Remove ICSU Remove the ICSU from the designated DS1 circuit pack’s
amphenol connector.
Re-use the existing cable attached to the ICSU.
5. Attach splitter Plug the splitter into the same connector just vacated by
the ICSU.
6. Attach ICSU Plug the ICSU into the connector on the splitter.
7. Reconnect
cable
Connect the H600-307 cable to the amphenol connector
on the ICSU.
8. Check
connections
Check that all Amphenol connections are good.
9. Secure splitter Secure the splitter to the carrier using the 4C retainer from
the ICSU.
10. Secure ICSU Secure the ICSU to the splitter with a long cable tie.
11. Terminate the
splitter ports J1
and J2
Insert a modular RJ45 plug in both ports J1 and J2. Do not
connect port J1 to port J2, but leave the other end of both
cords free. The modular RJ45 plug acts as an opening
plug and removes the 100- termination from port J1 and
J2 on the splitter.
12. Check DS1
Status 3 LED
After about 20 seconds the LEDs on the DS1 circuit pack
should go out, leaving only the GREEN STATUS 3 LED on.
13. Test the DS1
circuit pack
test board
UUCSS
Test the circuit pack.
If any one of Tests 138 - 145 fails, follow the repair
procedures listed in DEFINITY ECS Maintenance for R8r
14. Clear the error
events counters
clear
measurements
ds1
esf-error-events
UUCSS
Clear the error events counter.
Continued on next page