Troubleshooting
6-30Troubleshooting ATM-PNC
6
TN2305/TN2306 circuit pack
Did the TN2305/TN2306 come up correctly?
1. Review the LED conditions for the TN2305/TN2306 (refer to the
maintenance book for LED indications):
Do the TN2305/TN2306 LEDs indicate a normal operational state
(any of the following):
Active in the PPN
Standby in the PPN
Archangel mode in the EPN
Standby in the EPN
2. If after circuit pack insertion or a demand reset:
Do the TN2305/TN2306 LEDs indicate that it is booting?
Do the TN2305/TN2306 LEDs indicate it is downloading its DSPs?
Do the TN2305/TN2306 LEDs indicate that circuit pack is not
completely inserted?
Do the TN2305/TN2306 LEDs indicate a maintenance alarm?
3. Type
list configuration carrier
UUCC
and press Enter. See
Screen 6-11
(1b) and
Screen 6-12
(2a).
Screen 6-11. List configuration carrier 1b screen
list configuration carrier 1b
SYSTEM CONFIGURATION
Board Assigned Ports
Number Board Type Code Vintage u=unassigned t=tti p=psa
01B02 ATM PNC EI TN2305 HW02 FW007
01B04 DIGITAL LINE TN754C 000002 u u u u u u u u
01B05 ANALOG LINE TN746B 000010 u u u u u 06 u u
u u u u u u u u
01B06 DID TRUNK TN753 000021 u u u u u u u u
01B07 MAINTENANCE/TEST TN771D 000006 u 02 03 04
01B08 CO TRUNK TN747B 000018 u u u u u u u u
01B09 BRI LINE TN556B 000003 u u u u u u u u
u u u u u u u u
u u u u u u u u
01B10 DS1 INTERFACE TN767C 000003 u u u u u u u u
u u u u u u u u
u u u u u u u u