DEFINITY ECS Release 8.2 ATM Installation,
Upgrades, and Administration
555-233-124
Issue 1
April 2000
Troubleshooting
6-24Troubleshooting ATM-PNC
6
Screen 6-3. Screen output for list atm pnc command
Alternatively, type
list configuration
UUC
and press Enter (noncontrol
cabinets) to confirm the PPN and EPN circuit pack locations and correct
insertion.
2. Type
status pnc
and press
Enter. This display tells you which
TN2305/TN2306 circuit pack is active in a duplicated system and how
many alarms (if any) of each severity level have been logged for the circuit
pack. Screen 6-4
shows the output from this command.
Screen 6-4. Screen output for status pnc command
3. Type either
list configuration
UUC
(for the carrier in which the ATM
interface circuit packs reside) or
display circuit-packs
cabinet
(noncontrol cabinet) and press
Enter. This command tells you in more
detail what boards are in which slots in each cabinet and carrier. Verify
that the TN2305/TN2306s are physically located in the slots indicated on
the display. Screen 6-5
shows the output for the
display circuit-packs 1
command; Screen 6-6
shows the output for the
display circuit-packs 2
command.
list atm pnc Page 1 SPE A
ATM PNC
PNC A-PNC B-PNC
Connection # LOC LOC
1 01B02
2 02A01
status pnc
PORT NETWORK CONNECTIVITY
Duplicated? no
Software Locked?
Standby Busied?
Standby Refreshed?
Interchange Disabled?
A-PNC B-PNC
Mode: active Mode:
State of Health: functional State of Health:
Inter PN Index: 00.00.00 Inter PN Index:
Major Alarms: 0 Major Alarms:
Minor Alarms: 0 Minor Alarms:
Warning Alarms: 0 Warning Alarms: