Proxim CPN 65755B Webcam User Manual


 
Tsunami MP.11and MP.11a Installation and Management
CONFIGURATION RESTORE
You can restore the configuration of the MP.11/a by downloading a configuration file. The configuration
file contains the configuration information of an MP.11/a.
To download a configuration file through the Web Interface:
1. Set up the TFTP server as described in “TFTP Server Setup” on page 103.
2. Access the MP.11/a as described in “Web Interface Overview” on page 22.
3. Click the Commands button and the Download tab.
4. Fill in the following details:
Server IP Address <IP address TFTP server>
File Name <configuration file name>
File Type Config
File Operation Download
5. Click OK to start the file transfer.
The MP.11/a downloads the configuration file. The TFTP server program should show download activity
after a few seconds. When the download is complete and the system rebooted, the configuration is
restored.
SOFT RESET TO FACTORY DEFAULT
If necessary, you can reset the MP.11/a to the factory default settings. Resetting to default settings
means that you must configure the MP.11/a anew.
To reset to factory default settings using the Web Interface:
1. Click the Commands button and the Reset tab.
2. Click the Reset to Factory Default button.
The device configuration parameter values are reset to their factory default values.
If you do not have access to the MP.11/a, you can use the procedure described in “Hard Reset to
Factory Default” on page 106 as an alternative.
Chapter 7. Procedures 105
CPN 65755 Issue Date: August 2003