Tsunami MP.11and MP.11a Installation and Management
To view or change basic system information, click the Configure button on the left side of the Web
interface window, then click the System tab.
MP.11A OPTIONS
Selecting a Country
The Tsunami MP.11a provides a selectable Country field that automatically provides the allowed band
and frequencies for the selected country as well as, where applicable, Dynamic Frequency Selection
(DFS) and Transmit Power Control (TPC).
MP.11a kits sold in the United States are pre-configured to scan and display only the outdoor
frequencies permitted by the FCC. No other Country selections, channels, or frequencies may be
configured. MP.11a kits sold outside of the United States and Canada support the selection of a
Country by the professional installer.
Click the Configure button and the System tab; then select the appropriate country for your regulatory
domain.
Continue configuring settings as desired; then click the Commands button and the Reboot tab to save
and activate the settings.
Dynamic Frequency Selection
A country selection with DFS enabled causes the MP.11a Base Station to come up in scan mode. It
scans the available frequencies and channels to avoid radar and select a channel with the strongest
signal.
Note: Scanning is performed only on the frequencies allowed in the regulatory domain of the country
selected, when it is required for radar detection and avoidance.
The MP.11a Subscriber Unit also comes up in scan mode to scan all available frequencies to find a
Base Station with which it can register. Scanning, indicated by a flashing green LED (the fourth LED in
the case of the Base Station and the third LED for a Subscriber Unit), may take several minutes. When
the link is established, this LED turns off.
See “Dynamic Frequency Selection” on page 67 for more information.
Chapter 3. Management Overview 23
CPN 65755 Issue Date: August 2003