Q-Logic 59022-11 A 4-13 Switch User Manual


 
4 – Managing Switches
Displaying Switch Information
59022-11 A 4-11
0
Warning Temperature Non-configurable temperature threshold (65° Celsius)
above which a warning condition alarm is generated.
Failure Temperature Non-configurable temperature threshold (70° Celsius)
above which a failure condition alarm is generated.
NTP Client Enabled Enabled or disabled. Allows for switches to synchronize
their time a centralized server.
NTP Server Address The IP address of the centralized NTP server. Ethernet
connection to NTP server is required.
FDMI Enable Fabric Device Management Interface status. If enabled,
device information can be obtained, managed, and saved
through the fabric using Name Service Management
Server functions. SANsurfer Switch Manager will report
any and all FDMI information reported by the entry switch,
if FDMI is enabled on the entry switch. Refer to
”Displaying Detailed Device Information” on page 3-34 for
information about displaying FDMI information.
FDMI HBA Entry Limit Maximum number of HBAs that can be registered with a
switch.
Number of Donor Groups Total number of donor port groups. A donor group is a set
of ports on a switch that can donate buffer credits to each
other.
Embedded GUI SANsurfer Switch Manager web applet status. Enables or
disables the web applet on the switch.
Inactivity Timeout Number of minutes the switch waits before terminating an
idle command line interface session. Zero (0) disables the
time out threshold.
GUI Mgmt Enabled Switch management application status. If disabled, the
switch cannot be managed using the application.
Telnet Enabled Telnet client status
SSH Enabled Secure Shell status. If enabled, an encrypted data path is
provided for command line interface sessions.
SSL Enabled Secure Sockets Layer status. If enabled, encryption for
switch management application and CIM sessions is
provided.
Table 4-2. Switch Data Window Entries (Continued)
Entry Description