Q-Logic 59022-11 A 4-13 Switch User Manual


 
A – Command Line Interface
Show Command
59022-11 A A-95
0
Examples The following is an example of the Show Chassis command:
SANbox2 #> show chassis
Chassis Information
-------------------
BoardTemp (1) - Degrees Celsius 32
BoardTemp (2) - Degrees Celsius 36
FanStatus (1) Good
FanStatus (2) Good
PowerSupplyStatus (1) Good
PowerSupplyStatus (2) Good
HeartBeatCode 1
HeartBeatStatus Normal
The following is an example of the Show Domains command:
SANbox2 #> show domains
Principal switch is (remote): 10:00:00:60:69:50:0b:6c
Upstream Principal ISL is : 1
Domain ID List:
Domain 97 (0x61) WWN = 10:00:00:c0:dd:00:71:ed
Domain 98 (0x62) WWN = 10:00:00:60:df:22:2e:0c
Domain 99 (0x63) WWN = 10:00:00:c0:dd:00:72:45
Domain 100 (0x64) WWN = 10:00:00:c0:dd:00:ba:68
Domain 101 (0x65) WWN = 10:00:00:60:df:22:2e:06
Domain 102 (0x66) WWN = 10:00:00:c0:dd:00:90:ef
Domain 103 (0x67) WWN = 10:00:00:60:69:50:0b:6c
Domain 104 (0x68) WWN = 10:00:00:c0:dd:00:b8:b7
The following is an example of the Show Fabric command:
SANbox2 #> show fabric
Domain WWN Enet IP Addr FC IP Addr SymbolicName
------ --- ------------ ---------- ------------
16 (0x10) 10:00:00:c0:dd:00:77:81 10.20.68.11 0.0.0.0 gui sb1 .11
17 (0x11) 10:00:00:c0:dd:00:6a:2d 10.20.68.12 0.0.0.0 sw12
18 (0x12) 10:00:00:c0:dd:00:c3:04 10.20.68.160 0.0.0.0 sw .160
19 (0x13) 10:00:00:c0:dd:00:bc:56 10.20.68.108 0.0.0.0 Sb2 .108