Ricoh 2018D Printer User Manual


 
Preparations for Use as a Network Scanner
12
2
G
GG
G
Repeat steps
C
CC
C
to
F
FF
F
to make other settings.
H
HH
H
Press the {
{{
{Cancel}
}}
} key.
The main menu appears.
Scan Settings
This section explains how to set the
defaults for scan settings.
The scan settings consist of the fol-
lowing. For the list about settings and
defaults, see p.9 Scanner Features.
Default Scan Settings
Resolution and scan size can be set.
Resolution
Select the resolution from 100dpi,
200dpi, 300dpi, 400dpi, or 600dpi.
Scan Size
Select the size of the original to be
scanned.
When [Auto Detect] is selected, the
auto detect function of the ma-
chine is used to set the original
size.
When the size is specified, scan-
ning is performed for that size, re-
gardless of the actual size of the
original. The following sizes can be
selected:
A3S, A4R, A4S, A5R, A5S, 11
× 17S, 8
1
/
2
× 14S, 8
1
/
2
× 13S,
8
1
/
2
× 11R, 8
1
/
2
× 11S, 5
1
/
2
×
8
1
/
2
R, 5
1
/
2
× 8
1
/
2
S, B4 JISS
(Japanese Industrial Standard), B5
JISR, B5 JISS, Custom size
Note
When [Custom Size] is selected,
the dimensions of the scan area
(width and height) can be speci-
fied.
When selecting [Custom Size] for
[Scan Size], see p.13 Selecting a
custom size.
Original Setting
Note
This setting is available only
when you have installed the op-
tional ADF capable of scanning
both sides of a sheet (ARDF).
Set the default for whether origi-
nals are one-sided or two-sided
and if two-sided, the relationship
between those sides. When the
originals are always the same, set
this for the default to make opera-
tion easier. You can select [1 Sided
Original], [2 sided Orig.(T toT )]
(Top to Top), or [2 Sided Orig.(To
toB )] (Top to Bottom).
Reference
p.31 Original Orientation and
Scan Area
Mixed Orig. Sizes Priority
This setting determines whether
the original size is to be automati-
cally detected when originals of
different sizes are inserted in the
ADF. You can select [On] or [Off].
Note
If the original size is specified
when scanning, this setting is
ignored.
When [Off] is selected, [Auto De-
tect] is selected for [Scan Size],
and originals of different sizes
are placed in the ADF, the max-
imum size of the originals is de-
tected as the scan size.