Tektronix 2200 Switch User Manual


 
4-87
Floppy Disk Drive Operations
Loading (Recalling) Configuration Files from Disk
This procedure describes loading switcher configuration files. You
can load all or part of a stored switcher configuration.
1. Insert your diskette into the switcher disk drive.
2. Access the Disk Menu. Press the CHILD DIRECTORY button to
cause the switcher to read the diskette and list the parent
directory.
3. Press CHILD DIRECTORY again to display the “Config”
subdirectory and list its’ files.
4. Use the FILE SELECT soft knob to highlight file ” Config1.”
5. Press the LOAD FILE button. The Load File Menu displays.
6. You can select any combination of the six switcher parameters
listed at the bottom of the menu to LOAD or NO LOAD. To
include all switcher configuration data, select LOAD for all six
parameters listed.
7. Press the DO LOAD button.
8. You will now see the Confirm File Load Menu. Press DO LOAD
to confirm the configuration recall.
Viewing (Listing) Files and Directories
You can view the diskette contents by directory, file name, or file
extension.
1. Invoke the Disk Menu.
2. Press CHILD DIRECTORY to read the diskette.
3. Use the VIEW BY DIR to list subdirectories. Note that in this
view no files will be displayed
.