Tektronix 2200 Switch User Manual


 
2-17
Software Setup
Defining System Defaults
Use the Define Defaults Menu to change the default values that
are stored in memory and used when the switcher is turned on.
(You may also use the CLEAR WORK BUFR button). The values
stored in the User-Defined Default Buffer (battery-backed RAM)
are loaded into the Working Buffer when power is applied to the
switcher. This sets the initial state of the switcher parameters.
1. With the M/E SELECT button, select the M/E whose settings you
want to be used during power-up. (Only one set of values is
stored for the M/Es, therefore both M/Es will use the same
values at boot-up.)
2. On the switcher panel (including the selected M/E), set up the
switcher state that you want the switcher to assume when it is
turned on.
3. Press SET DEFAULT to enter the new default values.
4. Pressing the GVG DEFAULT button will restore the factory-set
default values to the switcher. These are stored in non-volatile
memory (ROM).
DEFINE DEFAULTS MENU
ME1
config / user prefs / define defaults
M/E
SELECT
SET
DEFAULT
ME2
GVG
DEFAULT
Set Default State to Current Switcher State. All M/Es will use ME1 settings
Set Default State to GVG Factory Default.