2-1
This section describes turning on the system, setting up user
preferences, and setting up system parameters.
Powering Up
The Model 2200 is designed for continuous operation. Use the
following procedures to power-up the switcher when it has been
turned off.
1. Turn the power switch on the front of the Signal Processor
Power Supply to the ON position. Verify that the power
supply voltage LEDs on the front of the Power Supply are lit
and that the fans in the Processor are on.
2. Raise the Control Panel and turn the power supply switch to
the ON position. Verify that the green RUN LED on the CPU
Board (located in the middle of the tub) is lit.
3. Verify that the Model 2200 sign-on logo is displayed on the
Menu Display.
4. Verify that the panel pushbutton lamps are on and that the
E-MEM and Transition subpanel readout LEDs are on.
If any of the above conditions are not present, turn the system
power off and refer to the Diagnostics and Troubleshooting
section in the Installation and Service manual.
2
Startup and Configuration