Xerox 12 All in One Printer User Manual


 
TECHNICAL INFORMATION 144 DOCUCOLOR 12 USER GUIDE
2
3
4
5
6
7
14
Environmental Requirements
Health and Safety Information
Standby Temperatures Minimum
14
o
F (-10
o
C) at 5% relative humidity
Maximum
104
o
F (40
o
C) at 95% relative humid-
ity
Operating Temperatures Minimum
50
o
F (10
o
C) at 15% relative humidity
Maximum
95
o
F (35
o
C) at 85% relative humidity
Maximum Altitude 10,000 feet (3050 meters) in normal configuration
Heat Output Operating 4080 BTUs per hour, average
Standby 2720 BTUs per hour, average
Noise Levels Standby 58.4 dB(A)
Impulse/Run Mode 71.0 dB(A)
Ozone Emissions Not to exceed 0.01 PPM in a 50 cubic meter room (continuous run,
according to UZ 62)
Ozone filter change at 320K copies
Dust Dust concentration during continuous run = 0.075 mg/cubic meter
Photoreceptor Type Organic
Product Safety This copier/printer complies with the corresponding regulation:
US/Canada: UL 1950, Third Edition
Europe: Low Voltage Directive (72/23/EEC) IEC 950 A1: 1993/
A2:IEC825
The copier/printer carries the CE symbol for the 220-240 V, 50 Hz
version.
RFI Emissions This copier/printer complies with the following:
US/Canada: FCC Class B, ICES-003 Class B
Europe: EMC Directive (89/336/EEC) -EN55022-A Class B,
EN61000-3-2.