AT-9000 Switch Command Line User’s Guide
1147
RMON ALARM
Syntax
rmon alarm
alarm_id oid.stats_id
interval
interval
delta|absolute rising-threshold
rising-threshold
event
rising_event_id
falling-threshold
falling-threshold
event
falling_event_id
[owner
owner
]
Parameters
alarm_id
Specifies the ID number of a new alarm. The range is 1 to 65535.
oid
Specifies the OID of the RMON statistic the alarm should monitor.
You can specify just one statistic.
stats_id
Specifies the ID number of the statistics group that is assigned to
the port the alarm is to monitor. You can specify just one statistics
group, and the group must already exist.
For more information on the OID and STATS_ID variables, refer to
“Creating RMON Alarms” on page 1134.
interval
Specifies the polling interval in seconds. The range is 1 to 65535
seconds.
delta
Specifies that the alarm is based on the difference between the
current value and preceding value of the designated statistic.
absolute
Specifies that the alarm is based on the current value of the
designated RMON statistic.
rising_threshold
Specifies the rising threshold which, when crossed, causes the
switch to perform the specified event. The range is 1 to 65535.
rising_event_id
Specifies the ID number of the event the switch is to perform when
the rising threshold is crossed. The event must already exist.
falling_threshold
Specifies the falling threshold which, when crossed, causes the
switch to perform the specified event. The range is 1 to 65535.