Baldor VS1MD Computer Drive User Manual


 
6-6 VS1MD AC Drive User Manual
The below example indicates the steps needed to move from parameter F35 to
Function Group 2.
6.7 Changing Between Parameters Within a Group
Each group contains parameters arranged in a linear list. The list can be navigated
using the Up and Down arrows.
Table 6.4 – Moving from F35 to Function Group 2
Procedure Sample Display
Step 1. When a parameter other than the first in a group is
displayed, you must initially go to the first parameter
of the group prior to going to the next group. For this
example, parameter F35 of Function Group 1 is
currently displayed and you want to go to Function
Group 2 (H Parameters).
Step 2. Press the left or right arrow and parameter F0 will be
displayed.
Step 3. Press the right arrow key to change to “Function
Group 2”.
Table 6.5 – Changing Between Parameters Withing a Group
Procedure Sample Display
Step 1. From the operation mode, press and hold down the
ENTER key for at least two seconds to change the
drive to the programming mode. The “PROG” LED
will illuminate indicating that the drive is in
programming mode. The drive will display the first
parameter of the “Display” group.
Step 2. Press the up arrow to display the next parameter.
Step 3. Press the up arrow again to display the next
parameter, continue until the desired parameter is
displayed.
Note that using the down arrow allows navigation through the parameters in
reverse order.