Baldor VS1MD Computer Drive User Manual


 
Using the Keypad 6-11
6.10 Reviewing the Fault Status in the Display Group
When a fault is active, this is annunciated on the drive by flashing the STOP/FAULT
LED. This procedure is used to review the active fault as well as certain conditions at
the time the fault occurred.
Table 6.10 – Reviewing Fault Status in the Display Group
Step 1. When an overcurrent condition has been detected by
the drive, a fault will be latched and the display will
show the condition.
Step 2. Press the ENTER key to see the frequency at which
the fault occurred. This example indicates that the
drive was outputting 30.00 Hz when the fault
occurred.
Step 3. Press the up arrow to view the output current during
the fault. This example indicates that the drive was
outputting 5.0 Amps when the fault occurred.
Step 4. Press the up arrow key again to view the operating
status of the drive when the fault occurred. This
example indicates that the drive was accelerating
when the fault occurred.
Step 5. Press the STOP/RESET button on the keypad to
reset the fault and the STOP/FAULT LED will
illuminate solid indicating that the fault is cleared and
that the drive is in the stopped condition. The display
will indicate that there is no longer a fault condition.
Frequency
Current
During
Accel
Display Group
STOP
RESET
Over-
current
trip