Baldor VS1MD Computer Drive User Manual


 
Parameter Descriptions 7-5
7.3 Basic Program Group Parameters
The Basic Program Group (P) contains the parameters most commonly used in
start-up.
Sets the code to jump directly to a specific parameter within the group.
Sets the motor type connected to the drive output side.
P0 Jump Code
Range: 30 -47
Default:
30
Access Tunable
P30 Motor HP Select
Range: 0.5
1
2
3
5
7.5
10
= 0.5 HP
= 1 HP
= 2 HP
= 3 HP
= 5 HP
= 7.5 HP
= 10 HP
Default:
Preset based on drive rating.
Access Configurable
See also:
P32 - P34
P32 Motor Rated Current
Range: 0.5 - 50 Amps
Default:
Preset based on drive rating
Access Configurable
See Also:
P30, P33, P34
Enter motor rated current on the nameplate.
P33 Pole Number
Range: 2, 4, 6, 8, 10, 12
Default:
4
Access Configurable
See Also:
P30, P32, P34
Select number of motor poles